10 Excavator Fault Self-Inspection Methods

 · 
10 Excavator Fault Self-Inspection Methods

1. There is oil in the water tank

① The oil cooler core is split.

② The water seal of the pump is destroyed and the drainage hole is blocked.

③ The cylinder cushion is damaged.

 

2. There is coolant in the bottom of the oil

① The oil cooler core is split.

② The cylinder cushion is broken.

③ There are cracks in the cylinder head or cylinder block.

 

3. Low oil pressure

① Lack of oil.

② diesel oil, coolant.

③ The oil filter element is obstructed.

④ oil pump suction tubing disclosed.

⑤ oil safety valve (bypass) stuck in the overflow form or spring break.

⑥ The oil pump is worn.

⑦ The clearance between the crankshaft or camshaft and the bearing bush is outstanding

 

4. The water temperature is too high

① Small coolant capacity.

② The thermostat is destroyed.

③ Loose belt, low fan speed.

④ The pump is damaged.

⑤ Overload operation of advocacy machine

⑥ Water tank internal or external infarction.

 

5. Generator not charging

① Battery damaged.

② charging circuit or grounding circuit fault.

③ advocating mechanical and electrical brush wear.

④ Regulator or rectifier secondary pipe damage.

⑤ The rotor (excitation coil) is damaged.

 

6. The hydraulic pipe shivers, the hydraulic pump is loud

① There is an atmosphere in the hydraulic pump.

② wear of the swash plate or plunger slipper in the hydraulic pump.

 

7. Walking wandering

① improper tuning of crawler tensification.

② the corresponding walking motor leakage, or reducer damage.

③ The hydraulic pump internal leakage, small flow.

④ walking control pilot circuit fault, or walking main circuit fault.

⑤ The center rotary comment inside the oil seal damage, string oil.

 

8. Slow walking speed

① The pilot control oil circuit or main oil circuit component faults.

② The pilot pump or hydraulic pump fault.

③ The oil seal in the center rotation is damaged and the oil is in string.

 

9. Walking and climbing inability, lack of digging power

① The main circuit, pilot circuit safety valve fault, low pressure.

② the corresponding safety relief valve, balance valve, buffer valve and other problems.

③ The hydraulic pump, pilot pump and hold valve internal leakage.

 

10. Electrical function of a certain circuit is not available

① The corresponding fuse is damaged.

② The circuit element is damaged or the conductor is faulty.

Leave a comment

Please note, comments need to be approved before they are published.

RECENT POSTS
RELATED POSTS

Featured Products

60100000 VOE60100000 Engine ECU for Volvo Excavators Loaders Graders - Sinocmp 60100000 VOE60100000 Engine ECU for Volvo Excavators Loaders Graders - Sinocmp
Sale
14518349 V-ECU Engine Controller_01 14518349 V-ECU Engine Controller_02
Sale
21695313 ECU Engine Controller_01 21695313 ECU Engine Controller_02
Sale
Controller Controller

Controller

As the brain behind the machine's operations, the controllers provide essential information and let you stay informed about operating parameters of your machine.

When choosing SINOCMP for your excavator controller needs, you can always expect:

Free Programming: We charge no fees for programming. All you need to do is offer the part number and VIN necessary to us.

Affordable Price: Our ECM controllers are offered in different conditions and pricing for you to choose, from genuine refurbished to aftermarket, all accessible and affordable without compromising on quality.

Hassle-Free Return & Refund: Besides a 12-month warranty, we also offer responsive and efficient return and exchange to ensure your pleasant shopping experience with us.

Shop Controller