Kobelco Error Code

 · 
Kobelco Error Code

As an excavator driver, it is inevitable to encounter an excavator running fault. Many errors are small, which will prompt for some error codes on the display. As long as we understand the meaning of these error codes, we can easily resolve these faults ourselves. Compared to looking for a maintenance master to help us check, we understand the code has been greatly shortened our time and economic costs.

Therefore, understanding the meaning of the error code plays a very important role in solving the problem of malfunction in the operation or maintenance of the excavator. In this article we will introduce the following models from SK-6E, SK200-2 / -3, SK200-6, SK210-8, SK330-6E, as follows:

 

Kobelco SK-6E Excavator Error Code

Error code    Fault description

        A-1      ROM data

  A-2       A poor adjustment

  B-1       Boom rise

  B-2       Big arm drop

  B-3       Arm extension

  B-4       Arm recovery

  B-6       Excavation

  B-7       Right rotation

  B-9       Walking right

  B-10     Walking left

  C-1       P1 pump

  C-2       P2 pump

  D-1       P1 neutral cut

  D-2       P2 neutral cut

  D-3       Go straight

  D-4       Small arm variable regeneration

  D-6       Small arm variable regeneration

 

Kobelco SK200-2/-3 Excavator Error Code

Error code    Fault description

        A-1       Bad ROM data (no electromechanical A adjustment)

  A-2       Electromechanical A poorly adjusted

  A-3       CPU exception

  B-1       Abnormal arm rise pressure sensor

  B-2       Abnormal arm pressure sensor abnormal

  B-3       Arm retracting pressure sensor abnormal

  B-4       Abnormal arm extension pressure sensor

  B-5        Bucket retraction pressure sensor abnormal

  B-6        Bucket extension pressure sensor is abnormal

  B-7        Swing pressure sensor is abnormal

  B-9        Right travel pressure sensor is abnormal

  B-10     Left travel pressure sensor is abnormal

  C-1       P1 oil pump pressure sensor is abnormal

  C-2       P2 oil pump pressure sensor is abnormal

  D-1       P1 Neutral cut-off proportional valve is abnormal

  D-2       P2 Neutral cut-off proportional valve is abnormal

  D-3       Straight running proportional valve abnormal

  D-4       Abnormal confluence proportional valve (only -2 models)

  D-5       Slow rotary proportional valve abnormal (only -2 models)

  D-6       Arm variable regenerative proportional valve abnormal (only -3 models)

 

Kobelco SK200-6 Excavator Fault Code 

Error code   Fault description

       1-1        The instrument communicates abnormally with the electromechanical controller

    1-2        Battery relay abnormal

  A-1       No electromechanical A adjustment

  A-2       Electromechanical A poorly adjusted

  B-1       Abnormal pressure sensor on the boom

  B-2       Abnormal arm pressure sensor abnormal

  B-3       Arm retracting pressure sensor abnormal

  B-4       Abnormal arm extension pressure sensor

  B-5       Bucket retraction pressure sensor abnormal

  B-6       Bucket extension pressure sensor is abnormal

  B-7       Right swing pressure sensor is abnormal

  B-8       Left rotation pressure sensor is abnormal

  B-9       Right travel pressure sensor is abnormal

  B-10     Left travel pressure sensor is abnormal

  B-11     P1 negative pressure sensor is abnormal

  B-12     P2 negative pressure sensor is abnormal

  B-15     Back pressure sensor abnormal

  C-1       P1 oil pump pressure sensor is abnormal

  C-2       P2 oil pump pressure sensor is abnormal

  D-1       P1 Neutral cut-off proportional valve is abnormal

  D-2       P2 Neutral cut-off proportional valve is abnormal

  D-3       Straight running proportional valve abnormal

  D-6       Arm variable regenerative proportional valve abnormal

  E-1        P1 oil pump proportional valve is abnormal

  E-2        P2 oil pump proportional valve is abnormal

  F-1        Booster solenoid valve is abnormal

  F-2        Rotary brake solenoid valve is abnormal

  F-3        Travel speed conversion solenoid valve is abnormal

  G-1       Stepper motor current is abnormal

  G-2       Stepper motor without starting point indexing

  G-3       Engine speed sensor is abnormal

       H-1       Throttle knob abnormal

 

Kobelco SK330-6E Excavator Fault Code

Error code    Fault description

  P0540    Preheater failure (open circuit / CND short circuit)

  P0540    Preheater failure (+B short circuit)

  P0617    Start switch circuit failure

  P0686    Main relay circuit failure

  P0629    Fuel supply solenoid valve circuit failure (+B short circuit), engine cannot start / engine stop

  P0628    Fuel pump solenoid valve circuit failure (full output mode), output drop

  P2635    Fuel pump abnormal pressure history

  P2635    Fuel pump solenoid stuck

  P0088    Common rail pressure abnormality, output drop

  P1601    Injector multi-point correction abnormality, output drop

  P0201    Injector 1 solenoid valve circuit open, output down / broken cylinder operation (1 time)

  P0202    Injector 2 solenoid valve circuit open, output down / broken cylinder operation (2 times)

  P0203   Injector 3 solenoid valve circuit open, output down / broken cylinder operation (3 times)

  P0204   Injector 4 solenoid valve circuit open, output down / broken cylinder operation (4 times)

  P0263   Cylinder correction fault 1

  P0266   Cylinder correction fault 2

  P0269   Cylinder correction fault 3

  P0272   Cylinder correction fault 4

  P0489   EGR valve linear solenoid valve 1 fault (open circuit / GND short circuit), output drop

  P0490   EGR valve linear solenoid valve 1 fault (VB short circuit), output drop

  P0404   EGR valve stuck 1, output decreased

  P0405   EGR valve safety sensor 1 fault (LO)

  P0406   Valve Safety Sensor 1 Fault (HI)

  P0234   Turbo is too large and output is falling

  P0217   Engine overheating, output drop

  P0219   Engine coast communication: U1001, CAN communication interruption (vehicle)

  P0611   ECU charging circuit failure (LO), output drop

  P0200   Defective ECU charging circuit (HI)

  P0605   ROM exception

  P0606   CPU failure, engine cannot start engine stop

  P0607   CPU monitoring IC is abnormal, output is degraded

 

Kobelco-8, Super 8 Excavator Fault Code

Error code   Fault description

  A015     No engine adjustment (A adjustment), or adjustment failed

  A025     Pump proportional valve adjustment (B adjustment) is not performed, or adjustment fails

  A035     No unloading valve adjustment (C adjustment), or adjustment failed

  A215     ROM adjustment data write data is abnormal

  A225     ROM adjustment data is written abnormally

  A235     ROM timer data write data is abnormal

  A245     ROM timing data is written abnormally

  A255     Proportional valve adjustment data write error

  B012     Boom rise pressure sensor abnormal output

  B013     Boom rise pressure sensor

  B014     Boom up pressure sensor

  B022     Boom drop pressure sensor abnormal output

  B023     Boom drop pressure sensor

  B024     Boom drop pressure sensor

  B032     Arm extended pressure sensor abnormal output

  B033     The arm extends out of the pressure sensor.

  B034     Arm extended pressure sensor short circuit

  B042     Arm recovery pressure sensor abnormal output

  B043     Arm recovery pressure sensor

  B044     Arm recovery pressure sensor power supply short circuit

  B052     Bucket excavation pressure sensor abnormal output

  B053     Bucket excavation pressure sensor

  B054     Bucket excavation pressure sensor

  B062     Bucket dumping pressure sensor abnormal output

  B063     Bucket dumping pressure sensor

  B064     Bucket dumping pressure sensor

  B072     Rotary pressure sensor abnormal output

  B073     Rotary pressure sensor

  B074     Rotary pressure sensor

  B092     Right travel pressure sensor abnormal output

  B093     Right travel pressure sensor

  B094     Right travel pressure sensor

  B102     Left travel pressure sensor abnormal output

  B013     Boom rise pressure sensor

  B014     Boom up pressure sensor

  B022     Boom drop pressure sensor abnormal output

  B023     Boom drop pressure sensor

  B024     Boom drop pressure sensor

  B032     Arm extended pressure sensor abnormal output

  B033     The arm extends out of the pressure sensor.

  B034     Arm extended pressure sensor short circuit

  B042     Arm recovery pressure sensor abnormal output

  B043     Arm recovery pressure sensor

  B044     Arm recovery pressure sensor power supply short circuit

  B052     Bucket excavation pressure sensor abnormal output

  B053     Bucket excavation pressure sensor

  B054     Bucket excavation pressure sensor

  B062     Bucket dumping pressure sensor abnormal output

  B063     Bucket dumping pressure sensor

  B064     Bucket dumping pressure sensor

  B072     Rotary pressure sensor abnormal output

  B073     Rotary pressure sensor

  B074     Rotary pressure sensor

  B092     Right travel pressure sensor abnormal output

  B093     Right travel pressure sensor

  B094     Right travel pressure sensor

  B102     Left travel pressure sensor abnormal output

  B103     Left travel pressure sensor

  B104     Left travel pressure sensor

  B113     Option selector position detection pressure sensor

  B114     Option selector position detection pressure sensor power supply short circuit

  B162     P1 side option pressure sensor abnormal output

  B163     Optional pressure sensor on the P1 side

  B164     P1 side option pressure sensor power supply short circuit

  B172     P2 side optional pressure sensor abnormal output

  B173     P2 side optional pressure sensor

  B174     P2 side option pressure sensor power supply short circuit

  C012     P1 pump pressure sensor abnormal output

  C013     P1 pump pressure sensor

  C014     P1 pump pressure sensor power supply short circuit

  C022     P2 pump pressure sensor abnormal output

  C023     P2 pump pressure sensor

  C024     P2 pump pressure sensor power supply short circuit

  C033     Big head pressure sensor

  C034     Big head pressure sensor

  C043     Boom pressure sensor

  C044     Boom pressure sensor short circuit

  D012     P1 unloading proportional valve output transistor ON faul

  D013     P1 unloading proportional valve

  D022     P2 unloading proportional valve output transistor ON fault

  D023     P2 unloading proportional valve

  D032     Walking straight proportional valve output transistor ON fault

  D033     Walking straight proportional valve

  D062     Arm recovery 2 speed proportional valve output transistor ON fault

  D063     Arm recovery 2 speed proportional valve

  E012     P1 pump proportional valve output transistor ON fault

  E013     P1 pump proportional valve

  E022     P2 pump proportional valve output transistor ON fault

  E023     P2 pump proportional valve

  F011     Work device boost solenoid valve Output transistor OFF Fault, short to ground

  F013     Work device boost solenoid valve Output transistor ON Fault, disconnection

  F021     Rotary parking solenoid valve Output transistor OFF Fault, short to ground

  F023     Rotary parking solenoid valve Output transistor ON Fault, disconnection

  F031     Walking 1-2 speed solenoid valve Output transistor OFF Fault, short to ground

  F033     Walking 1-2 speed solenoid valve Output transistor ON Fault, disconnection

  F041     Optional selector solenoid valve Output transistor OFF Fault, short to ground

  F043     Option selector output transistor ON fault, disconnection

  G032    The speed sensor directly input by the electromechanical controller exceeds the limit

  G033    The speed sensor directly input by the electromechanical controller is disconnected abnormally

  H014    Throttle potentiometer

  H023    Boom angle potentiometer

  H024    Boom angle potentiometer power supply short circuit

  H033    Arm angle potentiometer

  H034    Arm angle potentiometer power supply short circuit

  H091    Fuel sensor ground short circuit abnormal

  H093    Fuel sensor disconnection abnormality

  I111      CAN1 communication receiving abnormality (passive fault)

  I113      CAN1 communication reception error (contact interruption)

  I313      Instrument group communication receiving abnormality (contact interruption failure)

  K014    Battery relay contact sintering

  R014    Wiper motor arc prevents relay abnormality

  R024    Wiper motor forward relay abnormal

  R034    Wiper motor reverse relay abnormal

  R044    Sprinkler motor machine abnormalities

  R134    Rotating flash relay is abnormal

  R144    Rotating flash relay is abnormal

  R154    Abnormal walking alarm relay

  R164    Automatic idle stop relay 2 is abnormal

  R174    Engine forced stop relay abnormal

  R184    Lever lock relay abnormal

       R214    Safety relay abnormal


The above is the main fault code and description of several models of Kobelco's excavator. We hope to help you solve some problems encountered in maintenance or operation. If you still want to know the error codes of other digging brands, please leave a message below this article.

SINOCMP Black Friday Sale

6 comments

Ankit Kumar
Ankit Kumar

P0234 error in kobelco sk520

Roland
Roland

Good day Sir

What make C-1, oil pump pressure sensor is abnormal on a excavator kobelco.

Best regards

Roland

Roland
Roland

Hi

What cause the pump pressure to be abnormal?

Regards

Roland

Roland
Roland

Hi

What cause the pump pressure to be abnormal?

Regards

Roland

Ling LAM
Ling LAM

Please send me by email about the meaning of error code of KOBELCO EXCAVATOR MODEL: SK135SR-3 below:-

ERROR CODE: 01742

Chad
Chad

Code Z030

Leave a comment

Please note, comments need to be approved before they are published.

RECENT POSTS
RELATED POSTS

Featured Products

60100000 VOE60100000 Engine ECU for Volvo Excavators Loaders Graders - Sinocmp 60100000 VOE60100000 Engine ECU for Volvo Excavators Loaders Graders - Sinocmp
Sale
14518349 V-ECU Engine Controller_01 14518349 V-ECU Engine Controller_02
Sale
21695313 ECU Engine Controller_01 21695313 ECU Engine Controller_02
Sale
Controller Controller

Controller

As the brain behind the machine's operations, the controllers provide essential information and let you stay informed about operating parameters of your machine.

When choosing SINOCMP for your excavator controller needs, you can always expect:

Free Programming: We charge no fees for programming. All you need to do is offer the part number and VIN necessary to us.

Affordable Price: Our ECM controllers are offered in different conditions and pricing for you to choose, from genuine refurbished to aftermarket, all accessible and affordable without compromising on quality.

Hassle-Free Return & Refund: Besides a 12-month warranty, we also offer responsive and efficient return and exchange to ensure your pleasant shopping experience with us.

Shop Controller