As a professional supplier of construction machinery parts and solutions, SINOCMP understands that unplanned downtime due to engine issues can derail your project timeline and profitability. That’s why we’re breaking down common Komatsu engine fault codes to help you diagnose problems quickly, backed by our expertise in genuine and aftermarket parts support. Let’s dive into the most frequent codes, their causes, and how to address them, with insights to keep your equipment running at peak performance.

1. Fault Code [CA132]: Throttle Sensor Low Voltage Fault

User Code

E14

Failure

Throttle Sensor Low Voltage Fault (Engine Controller System)

Fault Code

CA132

Failure Details

Low voltage detected in the throttle sensor signal circuit.

Controller Response

  • If the fault occurs when the start switch is in the ON position, the controller will fix the voltage value to the level just before the fault was detected and continue operation.

  • If the start switch is turned to the ON position when the voltage is abnormally high, the controller will continue operation at 100% voltage.

Problem on Machine

The fuel control knob cannot control the engine speed.

Relevant Information

  • The signal voltage of the fuel control knob can be checked using the monitoring function (Code: 03000 Fuel Control Knob Voltage)
  • Method of reproducing the fault code: Turn the starting switch to the ON position.

2. Troubleshooting

The following are possible causes and detection methods:

Issues with The Throttle Sensor Power Supply System

  • Diagnosis method: If fault code [CA2186] is also indicated, perform fault diagnosis for [CA2186] first.

Issues with the Fuel Control Knob

  • Diagnosis method: Turn the start switch to the OFF position, be prepared, and then turn the start switch to the ON position.
  • Standard values:
 P20  Voltage
Between(1)-(3) Power Supply 4.75-5.25V
  • Note: If the voltage is abnormal, check the wire harness and controller as potential causes before making a judgment.

Wire Harness Around Fault (Short Circuit to Ground Circuit)

  • Diagnosis method: Turn the start switch to the OFF position, be prepared, and then perform diagnosis without turning the start switch ON.
  • Standard values:

    Wiring harness

    Resistance value

    Between CE02(female)(9) - P20(female)(2)

    Min.100Ω

Short Circuit in Wire Harness (with Another Wire Harness)

  • Diagnosis method: Turn the start switch to the OFF position, be prepared, and then perform diagnosis without turning the start switch to the ON position.
  • Standard values:

Wiring harness

Resistance value

Between CE02(female)(9) - P20(female)(2) and between CE02(female)(23) - P20(female)(3) 

Min.100Ω


Issues with Wire Harness Connectors

The connecting components between the fuel control knob, machine wire harness, and engine controller may be faulty. Check these connecting components directly:

  • Loose connectors, broken locks, or damaged seals.
  • Corroded, bent, damaged, pushed-in, or swollen pins.
  • Moisture or dirt in the connectors, or poor insulation in the connectors.

Faulty Engine Controller

  • Diagnosis method: Turn the start switch to the OFF position, be prepared, then turn the start switch to the ON position to perform fault diagnosis.
  • Standard values:
 CE02  Voltage
Between(22)-(23) Power Supply 4.75-5.25V

3. More Technical Support

If you need more information or further assistance, please feel free to let us know via live chat or email: service@sinocmp.com. We will reach out to you ASAP.

Related to:

Error Code List for Komatsu PC200-8, PC220-8 and PC220LC-8 Excavators

How to Clear Fault Code DXA8KA on Komatsu PC200-8

Dejar un comentario

Por favor, ten en cuenta que los comentarios deben ser aprobados antes de ser publicados.

MENSAJES RECIENTES
ARTÍCULOS RELACIONADOS

Productos Destacados

60100000 VOE60100000 Engine ECU for Volvo Excavators Loaders Graders - Sinocmp 60100000 VOE60100000 Engine ECU for Volvo Excavators Loaders Graders - Sinocmp
Venta
14518349 V-ECU Engine Controller_01 14518349 V-ECU Engine Controller_02
21695313 ECU Engine Controller_01 21695313 ECU Engine Controller_02
Controller - Sinocmp Controlador

Controlador

Como el cerebro detrás de las operaciones de la máquina, los controladores proporcionan información esencial y le permiten mantenerse informado sobre los parámetros operativos de su máquina.

Al elegir SINOCMP para las necesidades de su controlador de excavador, siempre puede esperar:

Programación gratuita: no cobramos tarifas por programación. Todo lo que necesita hacer es ofrecernos el número de pieza y VIN.

Precio asequible: nuestros controladores ECM se ofrecen en diferentes condiciones y precios para que usted elija, desde reacondicionados genuinos hasta el mercado de accesorios, todos accesibles y asequibles sin comprometer la calidad.

Devolución y reembolso sin problemas: además de una garantía de 12 meses, también ofrecemos un retorno e intercambio eficiente receptivos y eficientes para garantizar su experiencia de compra agradable con nosotros.

Tienda Controlador